PS024611-0408
Timer Operating Modes
The timers can be configured to operate in the following eleven modes:
ONE-SHOT Mode
In ONE-SHOT mode, the timer counts up to the 16-bit reload value stored in the Timer
Reload High and Low Byte registers. The Timer Input is the system clock. After reaching
this reload value, the timer generates an interrupt and the count value in the Timer High
and Low Byte registers is reset to
counting.
If the Timer Output alternate function is enabled, the Timer Output pin changes state for
one system clock cycle (from Low to High, then back to Low if
If the user chooses, the Timer Output can undergo a permanent state change upon
One-Shot timeout, as given below:
1. Set the
2. After starting the timer, set TPOL to the opposite value.
Follow the steps below to configure a timer for ONE-SHOT mode and initiate the count:
1. Write to the Timer Control registers to:
ONE-SHOT mode
TRIGGERED ONE-SHOT mode
CONTINUOUS mode
COUNTER mode
COMPARATOR COUNTER mode
PWM SINGLE OUTPUT mode
PWM DUAL OUTPUT mode
CAPTURE RESTART mode
CAPTURE COMPARE mode
COMPARE mode
GATED mode
ONE-SHOT mode.
(a) Disable the timer.
(b) Configure the timer for ONE-SHOT mode.
(c) Set the prescale value.
TPOL
bit in the Timer Control 1 register to the start value before beginning
0001h
. The timer is automatically disabled and stops
Z8FMC16100 Series Flash MCU
TPOL
Product Specification
Timer Operating Modes
= 0) at timer reload.
91