Table 65. Timer 0 Control 1 Register (T0CTL1)
BITS
FIELD
RESET
R/W
ADDR
PS024611-0408
Bit Position
[4]
TINSEL
[3–1]
PWMD
[0]
INCAP
Bit Position
[7]
TEN
TEN
R/W
7
0
Timer 0 Control 1 Register
The Timer 0 Control 1 (T0CTL1) register
prescaler value, and determines the timer operating mode.
Value (H)
Value (H)
000
001
010
011
100
101
110
0
1
111
0
1
0
1
TPOL
R/W
6
0
Description
Timer is enabled.
Timer is disabled.
Timer is enabled.
Timer Input Select
Timer input is the Timer input pin.
Timer input is the comparator output.
PWM Delay Value
This field is a programmable delay to control the number of additional
system clock cycles following a PWM or Reload compare before the
Timer Output or the Timer Output Complement is switched to the active
state. This field ensures a time gap between the deassertion of one
PWM output to the assertion of its complement.
No delay
2 cycles delay
4 cycles delay
8 cycles delay
16 cycles delay
32 cycles delay
64 cycles delay
128 cycles delay
Input Capture Event
Previous timer interrupt is not a result of a Timer Input Capture Event
Previous timer interrupt is a result of a Timer Input Capture Event.
Description
5
PRES
R/W
000
4
F07H
(Table
3
65) enables/disables the timer, sets the
Z8FMC16100 Series Flash MCU
2
Product Specification
Timer 0 Control Registers
TMODE
R/W
000
1
0
105