z8fmc16100 ZiLOG Semiconductor, z8fmc16100 Datasheet - Page 119

no-image

z8fmc16100

Manufacturer Part Number
z8fmc16100
Description
Z8 Encore Motor Control Flash Mcus
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z8fmc16100AKEG
Manufacturer:
LT
Quantity:
151
Part Number:
z8fmc16100AKEG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8fmc16100AKSG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8fmc16100QKEG
Manufacturer:
TOREX
Quantity:
2 000
PS024611-0408
Bit Position
[5:3]
PRES
Value (H)
000
001
010
011
100
101
110
111
Description
The timer input clock is divided by 2
to 7. The prescaler is reset each time the Timer is disabled. This insures
proper clock division each time the Timer is restarted.
Divide by 1
Divide by 2
Divide by 4
Divide by 8
Divide by 16
Divide by 32
Divide by 64
Divide by 128
PWM DUAL OUTPUT mode—If enabled, the Timer Output is set=TPOL
after PWM match and set=TPOL after Reload. If enabled the Timer
Output Complement takes on the opposite value of the Timer Output.
The PWMD field in the T0CTL1 register determines an optional added
delay on the assertion (Low to High) transition of both Timer Output and
the Timer Output Complement for deadband generation.
CAPTURE RESTART mode—If the timer is enabled the Timer Output
signal is complemented after timer Reload.
0 = Count is captured on the rising edge of the Timer Input signal.
1 = Count is captured on the falling edge of the Timer Input signal.
COMPARATOR COUNTER mode—If the timer is enabled the Timer
Output signal is complemented after timer Reload.
0 = Count is captured on the rising edge of the Timer Input signal.
1 = Count is captured on the falling edge of the Timer Input signal.
TRIGGERED ONE-SHOT mode—If the timer is enabled the Timer
Output signal is complemented after timer Reload.
0 = The timer triggers on a Low to High transition on the input.
1 = The timer triggers on a High to Low transition on the input.
PRES
Z8FMC16100 Series Flash MCU
, where PRES can be set from 0
Product Specification
Timer 0 Control Registers
107

Related parts for z8fmc16100