SAM9G25 Atmel Corporation, SAM9G25 Datasheet - Page 793

no-image

SAM9G25

Manufacturer Part Number
SAM9G25
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9G25

Flash (kbytes)
0 Kbytes
Pin Count
247
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
105
Ext Interrupts
105
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
3
Uart
7
Lin
4
Ssc
1
Ethernet
1
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
Yes
Adc Channels
12
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
DDR2/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No/Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
38.11.1
Name:
Address:
Access:
Reset:
• START: Send a START Condition
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a
write operation, a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
• STOP: Send a STOP Condition
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
• MSEN: TWI Master Mode Enabled
0 = No effect.
1 = If MSDIS = 0, the master mode is enabled.
Note:
• MSDIS: TWI Master Mode Disabled
0 = No effect.
1 = The master mode is disabled, all pending data is transmitted. The shifter and holding characters (if it contains data) are
transmitted in case of write operation. In read operation, the character being transferred must be completely received
before disabling.
11032A–ATARM–27-Jul-11
11032A–ATARM–27-Jul-11
SWRST
– In single data byte master read, the START and STOP must both be set.
– In multiple data bytes master read, the STOP must be set after the last data received but one.
– In master read mode, if a NACK bit is received, the STOP is automatically performed.
– In master data write operation, a STOP condition will be sent after the transmission of the current data is
31
23
15
7
finished.
Switching from Slave to Master mode is only permitted when TXCOMP = 1.
TWI Control Register
TWI_CR
0xF8010000 (0), 0xF8014000 (1), 0xF8018000 (2)
Write-only
0x00000000
QUICK
30
22
14
6
SVDIS
29
21
13
5
SVEN
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
STOP
25
17
9
1
SAM9G25
SAM9G25
START
24
16
8
0
793
793

Related parts for SAM9G25