SAM7X256 Atmel Corporation, SAM7X256 Datasheet - Page 67

no-image

SAM7X256

Manufacturer Part Number
SAM7X256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X256

Flash (kbytes)
256 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
13.2.6
Figure 13-9.
6120I–ATARM–06-Apr-11
if (URSTEN = 0) and
Peripheral Access
Reset Controller Status Register
(URSTIEN = 1)
Reset Controller Status and Interrupt
URSTS
NRSTL
rstc_irq
NRST
MCK
The Reset Controller status register (RSTC_SR) provides several status fields:
resynchronization
• RSTTYP field: This field gives the type of the last reset, as explained in previous sections.
• SRCMP bit: This field indicates that a Software Reset Command is in progress and that no
• NRSTL bit: The NRSTL bit of the Status Register gives the level of the NRST pin sampled on
• URSTS bit: A high-to-low transition of the NRST pin sets the URSTS bit of the RSTC_SR
• BODSTS bit: This bit indicates a brownout detection when the brownout reset is disabled
further software reset should be performed until the end of the current one. This bit is
automatically cleared at the end of the current software reset.
each MCK rising edge.
register. This transition is also detected on the Master Clock (MCK) rising edge (see
13-9). If the User Reset is disabled (URSTEN = 0) and if the interruption is enabled by the
URSTIEN bit in the RSTC_MR register, the URSTS bit triggers an interrupt. Reading the
RSTC_SR status register resets the URSTS bit and clears the interrupt.
(bod_rst_en = 0). It triggers an interrupt if the bit BODIEN in the RSTC_MR register enables
the interrupt. Reading the RSTC_SR register resets the BODSTS bit and clears the interrupt.
2 cycle
resynchronization
2 cycle
SAM7X512/256/128
RSTC_SR
read
Figure
67