EP2AGX45DF29I5N Altera, EP2AGX45DF29I5N Datasheet - Page 265

no-image

EP2AGX45DF29I5N

Manufacturer Part Number
EP2AGX45DF29I5N
Description
IC ARRIA II GX FPGA 45K 780FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX45DF29I5N

Number Of Logic Elements/cells
42959
Number Of Labs/clbs
1805
Total Ram Bits
3435
Number Of I /o
364
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
45125
# I/os (max)
364
Frequency (max)
500MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
45125
Ram Bits
3565158.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
Quantity:
201
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
Quantity:
853
Part Number:
EP2AGX45DF29I5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX45DF29I5N
0
Chapter 9: Configuration, Design Security, and Remote System Upgrades in Arria II GX Devices
Remote System Upgrades
Enabling Remote Update
© July 2010
Altera Corporation
1
1
Figure 9–22
the Arria II GX AS configuration scheme.
Figure 9–22. Remote System Upgrade Block Diagram for Arria II GX AS Configuration Scheme
You must set the mode select pins (MSEL[3..0]) to AS mode to use the remote
system upgrade in your system.
The MSEL pin settings vary for different configuration voltage standards and POR
delays. To connect MSEL[3..0], refer to
When using AS mode, you must select remote update mode in the Quartus II
software and insert the ALTREMOTE_UPDATE megafunction to access the circuitry.
For more information, refer to
You can enable remote update for Arria II GX devices in the Quartus II software
before design compilation (in the Compiler Settings menu). In remote update mode,
the auto-restart configuration after error option is always enabled. To enable remote
update in the project’s compiler settings, perform the following steps in the Quartus II
software:
1. On the Assignment menu, click Device. The Settings dialog box appears.
2. Click Device and Pin Options. The Device and Pin Options dialog box appears.
3. Click the Configuration tab.
4. From the Configuration scheme list, select Active Serial (you can also use
5. From the Configuration Mode list, select Remote
6. Click OK.
7. In the Settings dialog box, click OK.
Configuration Device)
shows a block diagram for implementing a remote system upgrade with
(Figure
“ALTREMOTE_UPDATE Megafunction” on page
9–23).
Nios II Processor
Configuration
or User Logic
Arria II GX
Device
Device
Serial
Table 9–2 on page
(Figure
Arria II GX Device Handbook, Volume 1
9–7.
9–23).
9–55.
9–45

Related parts for EP2AGX45DF29I5N