TRC105 RFM, TRC105 Datasheet - Page 13

IC TXRX 300MHZ-510MHZ 32TQFN

TRC105

Manufacturer Part Number
TRC105
Description
IC TXRX 300MHZ-510MHZ 32TQFN
Manufacturer
RFM
Datasheets

Specifications of TRC105

Frequency
300MHz ~ 510MHz
Data Rate - Maximum
200kbps
Modulation Or Protocol
FSK, OOK
Applications
General Purpose
Power - Output
13dBm
Sensitivity
-112dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
3mA
Current - Transmitting
30mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-TQFN
Wireless Frequency
300 MHz to 510 MHz
Output Power
13 dBm
Operating Supply Voltage
2.1 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
1.7 mA
Minimum Operating Temperature
- 40 C
Modulation
FSK, OOK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
583-1159-2
As shown in Figure 7, the demodulator section includes the FSK demodulator, the OOK demodulator, data and
clock recovery and the start pattern detection blocks.
If FSK is selected, the demodulation is performed by analyzing the phase between the I and Q limited signals at
the output of the base-band channels.
If OOK is selected, the demodulation is performed by comparing the RSSI output value stored in RXCFG14_
RSSI[7..0] register to the threshold which can be either a fixed value or a time-variant value depending on the
past history of the RSSI output. Table 9 gives the three main possible procedures, which can be selected via the
register MCFG01_RX_OOK[3..2]:
If the end-user application requires direct access to the output of the demodulator, then the RXCFG12_DCLK_
Dis[6] bit is set to 1 disabling the clock recovery. In this case the demodulator output is directly connected to the
DATA pin and the IRQ1 pin (DCLK) is set to low.
For proper operation of the TRC105 demodulator in FSK mode, the modulation index
meet the following condition:
where F
www.RFM.com
©2009-2010 by RF Monolithics, Inc.
DEV
Fixed Threshold
is the frequency deviation in hertz (Hz) and BR is the data rate in bits per second (b/s).
E-mail:
Average
Mode
Peak
info@rfm.com
MCFG01_RX_OOK[3..2]
00
01
10
β =
Technical support +1.800.704.6079
2*F
BR
RSSI output is compared with a fixed threshold stored in
RXCFG13_OOK_thresh
RSSI output is compared with a threshold which is at a fixed offset
below the maximum RSSI.
RSSI output is compared with the average of the last RSSI values.
DEV
Figure 7
Table 9
≥ 2
Description
β
of the input signal should
TRC105 - 11/01/10
Page 13 of 66

Related parts for TRC105