Setting the EXTHOLD bit extends the minimum setup and hold times for the SDA line. The minimum SDA
setup time defines the absolute minimum time that SDA is stable before SCL transitions from low-to-high.
The minimum SDA hold time defines the absolute minimum time that the current SDA value remains stable
after SCL transitions from high-to-low. EXTHOLD should be set so that the minimum setup and hold times
meet the SMBus Specification requirements of 250 ns and 300 ns, respectively. Table 22.2 shows the min-
imum setup and hold times for the two EXTHOLD settings. Setup and hold time extensions are typically
necessary when SYSCLK is above 10 MHz.
With the SMBTOE bit set, Timer 3 should be configured to overflow after 25 ms in order to detect SCL low
timeouts (see Section “22.3.4. SCL Low Timeout” on page 236). The SMBus interface will force Timer 3 to
reload while SCL is high, and allow Timer 3 to count when SCL is low. The Timer 3 interrupt service routine
should be used to reset SMBus communication by disabling and re-enabling the SMBus.
SMBus Free Timeout detection can be enabled by setting the SMBFTE bit. When this bit is set, the bus will
be considered free if SDA and SCL remain high for more than 10 SMBus clock source periods (see
Figure 22.4).
*Note: Setup Time for ACK bit transmissions and the MSB of all data transfers. When
EXTHOLD
using software acknowledgement, the s/w delay occurs between the time SMB0DAT
or ACK is written and when SI is cleared. Note that if SI is cleared in the same write
that defines the outgoing ACK value, s/w delay is zero.
0
1
Table 22.2. Minimum SDA Setup and Hold Times
Minimum SDA Setup Time
1 system clock + s/w delay*
T
low
11 system clocks
– 4 system clocks
or
Rev. 1.0
C8051F99x-C8051F98x
Minimum SDA Hold Time
12 system clocks
3 system clocks
239