PEB2256E INFINEON [Infineon Technologies AG], PEB2256E Datasheet - Page 328

no-image

PEB2256E

Manufacturer Part Number
PEB2256E
Description
E1/T1/J1 Framer and Line Interface Component for Long and Short Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
RDO3
CRC163
RAB3
HA13, HA03
LA3
Data Sheet
Note: Shorter frames are not reported.
Receive Data Overflow - HDLC Channel 3
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR5.RDO3/IMR5.RDO3).
CRC16 Compare/Check - HDLC Channel 3
0
1
Receive Message Aborted - HDLC Channel 3
This bit is set, if more than 5 contiguous 1-bits are detected.
High Byte Address Compare - HDLC Channel 3
Significant only if 2-byte address mode is selected.
In operating modes which provide high byte address recognition, the
FALC
of two individually programmable registers (RAH1, RAH2) and the
fixed values FE
Depending on the result of this comparison, the following bit
combinations are possible:
00 = RAH2 has been recognized
01 = Broadcast address has been recognized
10 = RAH1 has been recognized C/R=0 (bit 1)
11 = RAH1 has been recognized C/R=1 (bit 1)
Note: If RAH1, RAH2 contain identical values, a match is indicated by
Low Byte Address Compare - HDLC Channel 3
Significant in HDLC modes only.
The low byte address of a 2-byte address field, or the single address
byte of a 1-byte address field is compared with two registers. (RAL1,
RAL2).
0
1
CRC check failed; received frame contains errors.
CRC check o.k.; received frame is error-free.
®
"10" or "11".
RAL2 has been recognized
RAL1 has been recognized
compares the high byte of a 2-byte address with the contents
H
and FC
328
H
(broadcast address).
FALC56 V1.2
E1 Registers
PEB 2256
2002-08-27