Mode Register 2 (Read/Write)
Value after reset: 00
MODE2
MDS2(2:0)
HRAC2
DIV2
Data Sheet
MDS22
7
MDS21
0 =
1 =
Mode Select - HDLC Channel 2
The operating mode of the HDLC controller is selected.
000 Reserved
001 Reserved
010 One-byte address comparison mode (RAL1, 2)
011 Two-byte address comparison mode (RAH1, 2 and RAL1, 2)
100 No address comparison
101 One-byte address comparison mode (RAH1, 2)
110 Reserved
111 No HDLC framing mode 1
Receiver Active - HDLC Channel 2
Switches the HDLC receiver to operational or inoperational state.
0
1
Data Inversion - HDLC Channel 2
Setting this bit will invert the internal generated HDLC data stream.
0
1
H
Receiver inactive
Receiver active
Normal operation, HDLC data stream not inverted
HDLC data stream inverted
Automatic FISU transmission disabled.
Automatic FISU transmission enabled.