Editing the SESHELL.INI File
The user may wish to change the operation of SESHELL by editing the INI file. Always make a
backup copy of the file before editing it in case of error. The SESHELL.INI file must be saved as
an ASCII Text file. The following rules must be followed while altering the SESHELL.INI file:
not:
Following is an example of the format of a program entry in the SESHELL.INI file:
The “program” directive contains the name of the executable file.
The “cmdline” directive contains the path, the program name, and the command line arguments. If
the program locates in the same directory of the SESHELL, the path is not needed. A maximum
of four arguments are passed to the utility program. Any further arguments specified with the
“cmdline” directive are ignored.
Setting “dosshell” to yes causes SESHELL to load a DOS shell (or command line) after running
the specified utility.
Setting the “keeptsr” directive to “YES” allows the program to be loaded as a Terminate-and-Stay-
Resident program. However, the TSR program will be removed from resident memory on exiting
SESHELL.
The line length of the help text should not exceed 50 characters so that it will fit in the Description
Window.
1.8
SESHELL.EXE Shell Utility
UY7-6
1. Command line is executed.
2. DOS shell is entered (except when “dosshell = no”).
3. DOS shell terminates (by typing EXIT).
4. Any programs that attempted to stay resident in memory are forcefully released (except when “keeptsr =
5. Press the ESC key to exit SESHELL. Any programs that attempt to stay resident are forcefully released, in-
each program entry must be preceded by [begin]. Only lines following [begin] are valid;
help text must be sandwiched between [help] and [endhelp];
there MUST be at least one space in front of and after the “=” character, i.e.:
program = aaa.exe
program=aaa.exe
[begin]
program = ProgramName
cmdline = [ProgramPath] ProgramName Arg1 Arg2 Arg3 Arg4
cmdline = [ProgramPath] ProgramName Arg5
dosshell = no
keeptsr = yes
[help]
Sample Help text is found here.
[endhelp]
yes”)
cluding “keeptsr=yes”.
Typical Program Flow
S-MOS Systems, Inc. • Tel: (408) 922-0200 • Fax: (408) 922-0238 • http://www.smos.com