M69030 Asiliant Technologies, M69030 Datasheet - Page 253

no-image

M69030

Manufacturer Part Number
M69030
Description
Manufacturer
Asiliant Technologies
Datasheet

Specifications of M69030

Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Temperature (max)
70C
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M69030
Quantity:
5 510
Part Number:
M69030
Quantity:
5 510
Part Number:
M69030
Manufacturer:
CHIPS
Quantity:
20 000
Part Number:
M69030P
Manufacturer:
MIT
Quantity:
20 000
FR0F
read/write at I/O address 3D1h with index at I/O address 3D0h set to 0Fh
shadowed only for pipeline A
Note:
from a value programmed into this register (see bits 0-4 below) and is reset back to that count by read or
write accesses to graphics memory or standard VGA I/O. Reading or writing extended VGA registers does
not reset the counter. If no accesses occur, the counter increments until the end of its programmed interval
then activates either the ENABKL pin or Panel Off mode (as selected by bit-6 below). The timer count does
not need to be reloaded once programmed and the timer enabled. Any access to the chip with the timer
timed out (ENABKL active or Panel Off mode active) resets the timer and deactivates the ENABKL (or Panel
Off mode) pin. The activity timer uses the same clock as the power sequencing logic. The delay intervals
assume a 37.5 KHz clock. If using a 32KHz input, scale the delay intervals accordingly.
7
6
5
4-0
`efmp
A
B
Activity
Timer
This register controls the activity timer functions. The activity timer is an internal counter that starts
Enable Activity Timer
Activity Timer Action
Reserved (R/W)
Activity Timer Count
69030 Databook
(0)
7
Activity Timer Control Register
0: Disable activity timer (default on reset)
1: Enable activity timer
0: When the activity timer count is reached, the ENABKL pin is activated (driven low to turn
the backlight off)
1: When the activity timer count is reached, Panel Off mode is entered.
For a 37.5KHz power sequencing clock, the counter resolution is 28.1 seconds. The
minimum programmed value of 0 results in 28.1 seconds delay, and the maximum value of
1Eh results in a delay of 15 minutes.
Timer Action
6
Reserved
(R/W)
5
not shadowed for this pipeline
Flat Panel Registers
4
3
Activity Timer Count
2
Revision 1.3 11/24/99
1
0
15-15

Related parts for M69030