DS33R41+ Maxim Integrated Products, DS33R41+ Datasheet - Page 217

IC TXRX ETHERNET MAP 400-BGA

DS33R41+

Manufacturer Part Number
DS33R41+
Description
IC TXRX ETHERNET MAP 400-BGA
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of DS33R41+

Number Of Drivers/receivers
4/4
Protocol
T1/E1/J1
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
400-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 6: Transmit Message-End Event (TMEND). Set when the transmit HDLC controller has finished sending a
message. This is a latched bit and is cleared when read.
Bit 5: Receive Packet-End Event (RPE). Set when the HDLC controller detects either the finish of a valid
message (i.e., CRC check complete) or when the controller has experienced a message fault such as a CRC
checking error, or an overrun condition, or an abort has been seen. This is a latched bit and is cleared when read.
Bit 4: Receive Packet-Start Event (RPS). Set when the HDLC controller detects an opening byte. This is a
latched bit and is cleared when read.
Bit 3: Receive FIFO Above High-Watermark Condition (RHWM). Set when the receive 128-byte FIFO fills
beyond the high watermark as defined by the receive high-watermark register (TR.RHWMR).
Bit 2: Receive FIFO Not Empty Condition (RNE). Set when the receive 128-byte FIFO has at least 1 byte
available for a read.
Bit 1: Transmit FIFO Below Low-Watermark Condition (TLWM). Set when the transmit 128-byte FIFO empties
beyond the low watermark as defined by the transmit low-watermark register (TR.TLWMR).
Bit 0: Transmit FIFO Not Full Condition (TNF). Set when the transmit 128-byte FIFO has at least 1 byte
available.
7
0
TR.SR6, TR.SR7
HDLC #1 Status Register 6
HDLC #2 Status Register 7
20h, 22h
TMEND
6
0
RPE
5
0
217 of 335
RPS
4
0
RHWM
3
0
RNE
2
0
TLWM
1
0
TNF
0
0