DS33R41+ Maxim Integrated Products, DS33R41+ Datasheet - Page 212

IC TXRX ETHERNET MAP 400-BGA

DS33R41+

Manufacturer Part Number
DS33R41+
Description
IC TXRX ETHERNET MAP 400-BGA
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of DS33R41+

Number Of Drivers/receivers
4/4
Protocol
T1/E1/J1
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
400-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 7: Spare Code Detected Condition (LSPARE)
Bit 6: Loop-Down Code-Detected Condition (LDN)
Bit 5: Loop-Up Code-Detected Condition (LUP)
Bit 4: Loss-of-Transmit Clock Condition (LOTC)
Bit 3: Loss-of-Receive Clock Condition (LORC)
Bit 2: V5.2 Link Detected Condition (V52LNK)
Bit 1: Receive Distant MF Alarm Condition (RDMA)
Bit 0: Receive Remote Alarm Condition (RRA)
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
0 = interrupt masked
1 = interrupt enabled—interrupts on rising and falling edges
LSPARE
7
0
TR.IMR3
Interrupt Mask Register 3
1Bh
LDN
6
0
LUP
5
0
212 of 335
LOTC
4
0
LORC
3
0
V52LNK
2
0
RDMA
1
0
RRA
0
0

Related parts for DS33R41+