EP4SGX290KF40C3N Altera, EP4SGX290KF40C3N Datasheet - Page 936

IC STRATIX IV GX 290K 1517FBGA

EP4SGX290KF40C3N

Manufacturer Part Number
EP4SGX290KF40C3N
Description
IC STRATIX IV GX 290K 1517FBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX290KF40C3N

Number Of Logic Elements/cells
291200
Number Of Labs/clbs
11648
Total Ram Bits
17248
Number Of I /o
744
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1517-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2624

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX290KF40C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX290KF40C3N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX290KF40C3NB
Manufacturer:
ALTERA
0
5–90
Stratix IV Device Handbook Volume 2: Transceivers
PMA Controls Reconfiguration Duration When Using Method 1
The logical_channel_address port is used in Method 1. The write transaction and
read transaction duration is as follows:
For writing values to the following PMA controls, the busy signal is asserted for 260
reconfig_clk clock cycles for each of these controls:
For writing values to the following PMA controls, the busy signal is asserted for 520
reconfig_clk clock cycles for each of these controls:
For reading the existing values of the following PMA controls, the busy signal is
asserted for 130 reconfig_clk clock cycles for each of these controls. The data_valid
signal is then asserted after the busy signal goes low.
For reading the existing values of the following PMA controls, the busy signal is
asserted for 260 reconfig_clk clock cycles for each of these controls. The data_valid
signal is then asserted after the busy signal goes low.
PMA Controls Reconfiguration Duration When Using Method 2 or Method 3
The logical_channel_address port is not used in Method 2 and Method 3. The write
transaction duration and read transaction duration are as follows:
For writing values to the following PMA controls, the busy signal is asserted for 260
reconfig_clk clock cycles per channel for each of these controls:
tx_preemp_1t (pre-emphasis control first post-tap)
tx_vodctrl (voltage output differential)
rx_eqctrl (equalizer control)
rx_eqdcgain (equalizer DC gain)
tx_preemp_0t (pre-emphasis control pre-tap)
tx_preemp_2t (pre-emphasis control second post-tap)
tx_preemp_1t_out (pre-emphasis control first post-tap)
tx_vodctrl_out (voltage output differential)
rx_eqctrl_out (equalizer control)
rx_eqdcgain_out (equalizer DC gain)
tx_preemp_0t_out (pre-emphasis control pre-tap)
tx_preemp_2t_out (pre-emphasis control second post-tap)
tx_preemp_1t (pre-emphasis control first post-tap)
tx_vodctrl (voltage output differential)
rx_eqctrl (equalizer control)
rx_eqdcgain (equalizer DC gain)
Write Transaction Duration
Read Transaction Duration
Write Transaction Duration
Chapter 5: Dynamic Reconfiguration in Stratix IV Devices
February 2011 Altera Corporation
Dynamic Reconfiguration Duration