EP1S20F484C6N Altera, EP1S20F484C6N Datasheet - Page 558

IC STRATIX FPGA 20K LE 484-FBGA

EP1S20F484C6N

Manufacturer Part Number
EP1S20F484C6N
Description
IC STRATIX FPGA 20K LE 484-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S20F484C6N

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
361
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F484C6N
Manufacturer:
ALTERA
Quantity:
534
Part Number:
EP1S20F484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F484C6N
Manufacturer:
ALTERA
0
Architecture
6–8
Stratix Device Handbook, Volume 2
Multiplier Stage
The multiplier stage supports 9
(The multiplier stage also support smaller multipliers. See
Modes” on page 6–18
block can perform many multiplications in parallel.
The multiplier operands can be signed or unsigned numbers. Two
signals, signa and signb, indicate the representation of the two
operands. For example, a logic 1 on the signa signal indicates that data
A is a signed number; a logic 0 indicates an unsigned number. The result
of the multiplication is signed if any one of the operands is a signed
number, as shown in
The signa and signb signals affect the entire DSP block. Therefore, all
of the data A inputs feeding the same DSP block must have the same sign
representation. Similarly, all of the data B inputs feeding the same DSP
block must have the same sign representation. The multiplier offers full
precision regardless of the sign representation.
1
Pipeline Registers
The output from the multiplier can feed a pipeline register or be
bypassed. You can use pipeline registers for any multiplier size;
pipelining is useful for increasing the DSP block performance,
particularly when using subsequent adder stages.
1
Table 6–3. Multiplier Signed Representation
Unsigned
Unsigned
Signed
Signed
By default, the Altera Quartus
perform unsigned multiplication when the signa and signb
signals are not used.
In the DSP block, pipelining improves the performance of
36
pipelining adds latency but does not improve performance.
Data A
36 multipliers. For 18
Table
for details.) Based on the data width, a single DSP
6–3.
Unsigned
Unsigned
Signed
Signed
Data B
9, 18
18 multipliers and smaller,
®
II software sets the multiplier to
18, or 36
36 multiplication.
Altera Corporation
Unsigned
Signed
Signed
Signed
Result
“Operational
July 2005

Related parts for EP1S20F484C6N