OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 212

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
18.4.8 Go <address> <mode> (UART ISP)
18.4.9 Erase sector(s) <start sector number> <end sector number> (UART
Table 193. UART ISP Go command
ISP)
Table 194. UART ISP Erase sector command
Command
Input
Return Code CMD_SUCCESS |
Description
Example
Command
Input
Return Code CMD_SUCCESS |
Description
Example
G
Address: Flash or RAM address from which the code execution is to be started.
This address should be on a word boundary.
Mode: T (Execute program in Thumb Mode) | A (Execute program in ARM mode).
ADDR_ERROR |
ADDR_NOT_MAPPED |
CMD_LOCKED |
PARAM_ERROR |
CODE_READ_PROTECTION_ENABLED
This command is used to execute a program residing in RAM or flash memory. It
may not be possible to return to the ISP command handler once this command is
successfully executed. This command is blocked when code read protection is
enabled.
"G 0 A<CR><LF>" branches to address 0x0000 0000 in ARM mode.
E
Start Sector Number
End Sector Number: Should be greater than or equal to start sector number.
BUSY |
INVALID_SECTOR |
SECTOR_NOT_PREPARED_FOR_WRITE_OPERATION |
CMD_LOCKED |
PARAM_ERROR |
CODE_READ_PROTECTION_ENABLED
This command is used to erase one or more sector(s) of on-chip flash memory. The
boot block can not be erased using this command. This command only allows
erasure of all user sectors when the code read protection is enabled.
"E 2 3<CR><LF>" erases the flash sectors 2 and 3.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Chapter 18: EM773 Flash memory programming firmware
UM10415
© NXP B.V. 2010. All rights reserved.
212 of 310

Related parts for OM13005,598