OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 209

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
18.4.1 Unlock <Unlock code> (UART ISP)
18.4.2 Set Baud Rate <Baud Rate> <stop bit> (UART ISP)
18.4.3 Echo <setting> (UART ISP)
18.4.4 Write to RAM <start address> <number of bytes> (UART ISP)
Table 186. UART ISP Unlock command
Table 187. UART ISP Set Baud Rate command
Table 188. UART ISP Echo command
The host should send the data only after receiving the CMD_SUCCESS return code. The
host should send the check-sum after transmitting 20 UU-encoded lines. The checksum is
generated by adding raw data (before UU-encoding) bytes and is reset after transmitting
20 UU-encoded lines. The length of any UU-encoded line should not exceed
61 characters(bytes) i.e. it can hold 45 data bytes. When the data fits in less then
20 UU-encoded lines then the check-sum should be of the actual number of bytes sent.
The ISP command handler compares it with the check-sum of the received bytes. If the
check-sum matches, the ISP command handler responds with "OK<CR><LF>" to
Command
Input
Return Code
Description
Example
Command
Input
Return Code
Description
Example
Command
Input
Return Code
Description
Example
U
Unlock code: 23130
CMD_SUCCESS |
INVALID_CODE |
PARAM_ERROR
This command is used to unlock Flash Write, Erase, and Go commands.
"U 23130<CR><LF>" unlocks the Flash Write/Erase & Go commands.
B
Baud Rate: 9600 | 19200 | 38400 | 57600 | 115200 | 230400
Stop bit: 1 | 2
CMD_SUCCESS |
INVALID_BAUD_RATE |
INVALID_STOP_BIT |
PARAM_ERROR
This command is used to change the baud rate. The new baud rate is effective
after the command handler sends the CMD_SUCCESS return code.
"B 57600 1<CR><LF>" sets the serial port to baud rate 57600 bps and 1 stop bit.
A
Setting: ON = 1 | OFF = 0
CMD_SUCCESS |
PARAM_ERROR
The default setting for echo command is ON. When ON the ISP command handler
sends the received serial data back to the host.
"A 0<CR><LF>" turns echo off.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Chapter 18: EM773 Flash memory programming firmware
10
UM10415
© NXP B.V. 2010. All rights reserved.
209 of 310