OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 128

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
Fig 26. Format and states in the Slave Transmitter mode
10.11.5.1 I2STAT = 0xF8
10.11.5.2 I2STAT = 0x00
10.11.5 Miscellaneous states
reception of the own
Slave address and
one or more Data
bytes all are
acknowledged
last data byte
transmitted. Switched
to Not Addressed
Slave (AA bit in
I2CON = “0”)
arbitration lost as
Master and
addressed as Slave
DATA
n
There are two I2STAT codes that do not correspond to a defined I
Table
This status code indicates that no relevant information is available because the serial
interrupt flag, SI, is not yet set. This occurs between other states and when the I
is not involved in a serial transfer.
This status code indicates that a bus error has occurred during an I
bus error is caused when a START or STOP condition occurs at an illegal position in the
format frame. Examples of such illegal positions are during the serial transfer of an
address byte, a data byte, or an acknowledge bit. A bus error may also be caused when
external interference disturbs the internal I
set. To recover from a bus error, the STO flag must be set and SI must be cleared. This
A
135). These are discussed below.
S
from Master to Slave
from Slave to Master
any number of data bytes and their associated
Acknowledge bits
this number (contained in I2STA) corresponds to a defined state of
the I
2
C bus
SLA
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
R
A8H
B0H
A
A
DATA
B8H
2
A
C block signals. When a bus error occurs, SI is
DATA
Chapter 10: EM773 I2C-bus interface
C8H
C0H
A
A
P OR S
ALL ONES
2
C hardware state (see
2
C serial transfer. A
UM10415
© NXP B.V. 2010. All rights reserved.
P OR S
2
128 of 310
C block

Related parts for OM13005,598