DF3048BVX25V Renesas Electronics America, DF3048BVX25V Datasheet - Page 524

MCU 3/5V 128K PB-FREE 100-TQFP

DF3048BVX25V

Manufacturer Part Number
DF3048BVX25V
Description
MCU 3/5V 128K PB-FREE 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheets

Specifications of DF3048BVX25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF3048BVX25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface
Receiving Multiprocessor Serial Data: Figure 13.12 shows a sample flowchart for receiving
multiprocessor serial data and indicates the procedure to follow.
Rev. 3.00 Sep 27, 2006 page 496 of 872
REJ09B0325-0300
No
No
No
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Figure 13.12 Sample Flowchart for Receiving Multiprocessor Serial Data (1)
Read receive data from RDR
Read receive data from RDR
Set MPIE bit to 1 in SCR
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit to 0 in SCR
Finished receiving?
FER
FER
Start receiving
RDRF = 1?
RDRF = 1?
Own ID?
Initialize
ORER = 1
End
ORER = 1
Yes
No
Yes
No
Yes
Yes
Yes
Yes
3
1
2
No
(continued on next page)
Error handling
4
5
1.
2.
3.
4.
5.
SCI initialization: the receive data function
of the RxD pin is selected automatically.
ID receive cycle: set the MPIE bit to 1 in SCR.
SCI status check and ID check: read SSR,
check that the RDRF flag is set to 1, then read
data from RDR and compare with the
processor’s own ID. If the ID does not match,
set the MPIE bit to 1 again and clear the
RDRF flag to 0. If the ID matches, clear the
RDRF flag to 0.
SCI status check and data receiving: read
SSR, check that the RDRF flag is set to 1,
then read data from RDR.
Receive error handling and break detection:
if a receive error occurs, read the
ORER and FER flags in SSR to identify the error.
After executing the necessary error handling,
clear the ORER and FER flags both to 0.
Receiving cannot resume while either the ORER
or FER flag remains set to 1. When a framing
error occurs, the RxD pin can be read to detect
the break state.