ATXMEGA16A4-CUR Atmel, ATXMEGA16A4-CUR Datasheet - Page 222

MCU AVR 16+4KB FLASH 49VFBGA

ATXMEGA16A4-CUR

Manufacturer Part Number
ATXMEGA16A4-CUR
Description
MCU AVR 16+4KB FLASH 49VFBGA
Manufacturer
Atmel
Series
AVR® XMEGAr
Datasheets

Specifications of ATXMEGA16A4-CUR

Core Processor
AVR
Core Size
8/16-Bit
Speed
32MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 3.6 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
49-VFBGA
For Use With
ATAVRONEKIT - KIT AVR/AVR32 DEBUGGER/PROGRMMRATSTK600 - DEV KIT FOR AVR/AVR32770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAG770-1004 - ISP 4PORT FOR ATMEL AVR MCU SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATXMEGA16A4-CUR
Manufacturer:
Atmel
Quantity:
10 000
19.9.6
19.9.7
8077H–AVR–12/09
ADDR - TWI Master Address Register
DATA -TWI Master Data Register
When the Address (ADDR) register is written with a slave address and the R/W-bit while the bus
is idle, a START condition is issued, and the 7-bit slave address and the R/W-bit are transmitted
on the bus. If the bus is already owned when ADDR is written, a Repeated START is issued. If
the previous transaction was a Master Read and no acknowledge is sent yet, the Acknowledge
Action is sent before the Repeated START condition.
After completing the operation and the acknowledge bit from the slave is received, the SCL line
is forced low if arbitration was not lost. The WIF is set.
If the Bus State is unknown when ADDR is written. The WIF is set, and the BUSERR flag is set.
All TWI master flags are automatically cleared when ADDR is written. This includes BUSERR,
ARBLOST, RIF, and WIF. The Master ADDR can be read at any time without interfering with
ongoing bus activity.
The data (DATA) register is used when transmitting and receiving data. During data transfer,
data is shifted from/to the DATA register and to/from the bus. This implies that the DATA register
cannot be accessed during byte transfers, and this is protected in hardware. The Data register
can only be accessed when the SCL line is held low by the master, i.e. when CLKHOLD is set.
In Master Write mode, writing the DATA register will trigger a data byte transfer, followed by the
master receiving the acknowledge bit from the slave. The WIF and the CLKHOLD flag are set.
In Master Read mode the RIF and the CLKHOLD flag are set when one byte is received in the
DATA register. If Smart Mode is enabled, reading the DATA register will trigger the bus opera-
tion as set by the ACKACT bit. If a bus error occurs during reception the WIF and BUSERR flag
are set instead of the RIF.
Accessing the DATA register will clear the master interrupt flags and the CLKHOLD flag.
Bit
+0x05
Read/Write
Initial Value
Bit
+0x06
Read/Write
Initial Value
R/W
R/W
7
0
7
0
R/W
R/W
6
0
6
0
R/W
R/W
5
0
5
0
R/W
R/W
4
0
4
0
ADDR[7:0]
DATA[7:0]
R/W
R/W
3
0
3
0
R/W
R/W
2
0
2
0
R/W
R/W
1
0
1
0
XMEGA A
R/W
R/W
0
0
0
0
ADDR
DATA
222