Specifications of ATXMEGA16A4-CUR

Core Processor
AVR
Core Size
8/16-Bit
Speed
32MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 3.6 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
49-VFBGA
For Use With
ATAVRONEKIT - KIT AVR/AVR32 DEBUGGER/PROGRMMRATSTK600 - DEV KIT FOR AVR/AVR32770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAG770-1004 - ISP 4PORT FOR ATMEL AVR MCU SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATXMEGA16A4-CUR
Manufacturer:
Atmel
Quantity:
10 000
14.7.2
14.7.3
8077H–AVR–12/09
Frequency Capture
Pulse-width Capture
Selecting the frequency capture event action, makes the enabled capture channel perform an
input capture and restart on positive edge events. This enables Timer/Counter to use capture to
measure the period or frequency of a signal directly. The capture result will be the time, T, from
the previous Timer/Counter restart and until the event occurred. This can be used to calculate
the frequency, f, of the signal:
Figure 14-10 on page 158
nal signal.
Figure 14-10. Frequency capture of an external signal
Since all capture channels uses the same Counter (CNT), only one capture channels must be
enabled at a time. If two capture channels are used with different source, the Counter will be
restarted on positive edge events from both input sources, and the result from the input capture
will have no meaning.
Selecting the pulse-width measure event action makes the enabled compare channel perform
the input capture action on falling edge events and the restart action on rising edge events. The
counter will then start at zero at every start of a pulse and the input capture will be performed at
the end of the pulse. The event source must be an I/O pin and the sense configuration for the pin
must be set up to generate an event on both edges.
ple where the pulse width is measured twice for an external signal.
f
=
external signal
events
CNT
1
-- -
T
MAX
BOT
shows an example where the Period is measured twice for an exter-
Period (T)
Figure 14-11 on page 159
XMEGA A
shows and exam-
"capture"
158