peb2035 ETC-unknow, peb2035 Datasheet - Page 98

no-image

peb2035

Manufacturer Part Number
peb2035
Description
Communications Advanced Cmos Frame Aligner
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2035
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035N
Manufacturer:
SIEMENS
Quantity:
25
Part Number:
peb2035N
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2035N
Manufacturer:
MIENENS
Quantity:
20 000
Part Number:
peb2035N
Quantity:
50
Part Number:
peb2035N-V4.1
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035N-VA3
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 076
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 087
Part Number:
peb2035NV4.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
1 000
Part Number:
peb2035P
Manufacturer:
INFINEON
Quantity:
1 000
EXLS ... External Loss Of Frame
SIM ... Alarm Simulation
Mode Register (WRITE)
MODE
CTM ... Select Channel Translation Mode
SIGM ... Select Signaling Mode
Semiconductor Group
0 ... Channel translation mode 0
1 ... Channel translation mode 1
0 ... CCS/CAS-CC mode
1 ... CAS-BR mode
With a low to high transition a new frame search will be started. This has the meaning of a
general reset of the internal frame alignment unit. Synchronous state is reached only if there
is one definite framing candidate. In the case of multiple candidates, the setting of the bit
CCR.FRS forces the receiver to lock onto the next available framing position.
Setting/resetting this bit initiates internal error simulation of: AIS, no signal, loss of
synchronization, slip, parity, framing errors, CRC errors, code violations. The error counters
FEC, CVC, CEC will be incremented.
The selection of simulated alarms is done via the error simulation counter: ASR.SC which
will be incremented with each setting of bit CCR.SIM. For complete checking of the alarm
indications eight simulation steps are necessary (ASR.SC = 0 after a complete simulation).
For selection of clear channels refer to bit CPY.SWTCH and Clear Channel Banks
CCB1 ... CCB3.
7
CTM
SIGM
CODE PMOD
98
CRC
OPT
IMOD
XAIS
0
PEB 2035
(01)