peb2035 ETC-unknow, peb2035 Datasheet - Page 11

no-image

peb2035

Manufacturer Part Number
peb2035
Description
Communications Advanced Cmos Frame Aligner
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2035
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035N
Manufacturer:
SIEMENS
Quantity:
25
Part Number:
peb2035N
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2035N
Manufacturer:
MIENENS
Quantity:
20 000
Part Number:
peb2035N
Quantity:
50
Part Number:
peb2035N-V4.1
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035N-VA3
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 076
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 087
Part Number:
peb2035NV4.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
1 000
Part Number:
peb2035P
Manufacturer:
INFINEON
Quantity:
1 000
1.3
P-LCC
Pin No.
6
7
Semiconductor Group
Pin Definitions and Functions (cont’d)
P-DIP
Pin No.
4
5
Symbol
RCHPY /
AFR
RFSPQ
Input (I)
Output (O)
O
O
Function
Receive Channel Parity
Even/odd parity signal which supplements the
number of ones of a received channel to an even/
odd quantity while sending channel data to output
RDO. The parity type is programmed by bit
RC0.RPYS.
PCM 24: Additional Function Receive
If enabled via bit ACR.DLC, this output provides a
4-kHz signal which marks the DL-bit position
within the data stream on RDO. It can be used as
receive strobe signal for external data link
controllers.
Receive Frame Synchronous Pulse (active low)
Framing pulse derived from the received PCM
route signal. During loss of synchronization (bit
RSR.LOS), this pulse is suppressed (not
influenced during alarm simulation).
Pulse frequency: 8 kHz
Pulse width:
11
488 ns [PCM 30]
648 ns [PCM 24]
PEB 2035