peb2035 ETC-unknow, peb2035 Datasheet - Page 56

no-image

peb2035

Manufacturer Part Number
peb2035
Description
Communications Advanced Cmos Frame Aligner
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2035
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035N
Manufacturer:
SIEMENS
Quantity:
25
Part Number:
peb2035N
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2035N
Manufacturer:
MIENENS
Quantity:
20 000
Part Number:
peb2035N
Quantity:
50
Part Number:
peb2035N-V4.1
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035N-VA3
Manufacturer:
SIMENS
Quantity:
20 000
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 076
Part Number:
peb2035NV4.1
Manufacturer:
SIEMENS
Quantity:
5 087
Part Number:
peb2035NV4.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
peb2035P
Manufacturer:
SIEMENS
Quantity:
1 000
Part Number:
peb2035P
Manufacturer:
INFINEON
Quantity:
1 000
Signaling Support
The above signals may be used to support different signaling applications for CCS, CAS-CC, or
CAS-BR. For each method, different ways of access to signaling data are implemented:
Access via
a. an intelligent controller without the need of supporting signals (e.g. SAB 82525, HSCX)
b. a controller supported by the ACFA
c. a DMA controller
d. the board microprocessor
a. Access via an Intelligent Controller
Applications: CCS, (CAS-CC)
The intelligent controller is able to locate the signaling data on the system internal highway by itself
when supplied with the synchronous pulse SYPQ of the system (see figure 9). In PCM 24
applications, the normally unused input XSIG has to be connected to XDI.
Semiconductor Group
AFR
AFT
O
O
I
PCM 24: Additional Function Receive
If enabled via bit ACR.DLC, this signal provides a 4-kHz DL clock which
marks the DL-bit position within the data stream at RDO.
PCM 24: Additional Function Transmit
If bit ACR.EXMF is reset, its function is equivalent to AFR for the transmit
direction.
If bit ACR.EXMF is set, this input signal can be used to synchronize the
transmitter of the ACFA externally for multiframe begin.
56
PEB 2035