SAM3X8E Atmel Corporation, SAM3X8E Datasheet - Page 1180

no-image

SAM3X8E

Manufacturer Part Number
SAM3X8E
Description
Manufacturer
Atmel Corporation
Datasheets
• PBK: Pipe Banks
This field contains the number of banks for the pipe.
For control endpoints, a single-bank pipe (0b00) should be selected.
This field is cleared upon sending a USB reset.
• ALLOC: Pipe Memory Allocate
Writing a one to this bit will allocate the pipe memory.
Writing a zero to this bit will free the pipe memory.
This bit is cleared when a USB Reset is requested.
Refer to the DPRAM Management chapter for more details.
1180
1180
Value
0
1
2
3
SAM3X/A
SAM3X/A
1_BANK
2_BANK
3_BANK
Name
Description
Single-bank pipe
Double-bank pipe
Triple-bank pipe
Reserved
11057A–ATARM–17-Feb-12
11057A–ATARM–17-Feb-12

Related parts for SAM3X8E