HD6417712BPV Renesas Electronics America, HD6417712BPV Datasheet - Page 711

MPU 1.5/3.3V 0K PB-FREE 256-BGA

HD6417712BPV

Manufacturer Part Number
HD6417712BPV
Description
MPU 1.5/3.3V 0K PB-FREE 256-BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH Ethernetr
Datasheet

Specifications of HD6417712BPV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
200MHz
Connectivity
EBI/EMI, Ethernet, FIFO, SCI, SIO
Peripherals
DMA, POR, WDT
Number Of I /o
24
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
256-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417712BPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
18.3.30 Receive/Relay Function Set Register (Port 1 to 0) (TSU_FWSL1)
TSU_FWSL1 sets the processing method of each frame in port 1 reception and port 1 to 0 relay
operations. In receiving a frame, the processing method can be determined by referring to the
CAM evaluation results when the multicast frame and the destination are other than this LSI. (For
details, refer to section 18.4.4, CAM Function.) Writing to this register is prohibited, after relay
operations have been enabled once (after the FWEN0 in TSU_FWEN0 or the FWEN1 in
TSU_FWEN1 is set to 1).
Bit
7 to 0
Bit
31 to 12 
11
10
9
Bit Name
Bit Name
FW41
FW31
FW21
Initial
Value
All 0
Initial
Value
All 0
0
0
0
R/W
R
R/W
R
R/W
R/W
R/W
Description
Reserved
These bits are always read as 0. The write value
should always be 0.
Description
Reserved
These bits are always read as 0. The write value
should always be 0.
Sets the processing method when frames from port 1
are addressed to this LSI
0: Frames are not relayed
1: Frames are relayed to port 0
Sets the processing method when frames from port 1
are Broadcast.
0: Frames are not relayed
1: Frames are relayed to port 0
Sets the processing method when frames from port 1
are multicast.
0: CAM hit: Frames are relayed to port 0
1: CAM hit: Frames are not relayed
CAM mishit: Frames are not relayed
CAM mishit: Frames are relayed to port 0
Rev. 1.00 Dec. 27, 2005 Page 667 of 932
Section 18 Ethernet Controller (EtherC)
REJ09B0269-0100

Related parts for HD6417712BPV