PIC18C658 MICROCHIP [Microchip Technology], PIC18C658 Datasheet - Page 152

no-image

PIC18C658

Manufacturer Part Number
PIC18C658
Description
High-Performance Microcontrollers with CAN Module
Manufacturer
MICROCHIP [Microchip Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18C658-1/CL
Manufacturer:
Microchip
Quantity:
6
Part Number:
PIC18C658-1/L
Manufacturer:
Microchip
Quantity:
6
Part Number:
PIC18C658-E/L
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18C658-E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18C658-ES
Manufacturer:
Microchip
Quantity:
131
Part Number:
PIC18C658-I/L
Manufacturer:
Microchip
Quantity:
385
Part Number:
PIC18C658-I/L
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18C658-I/L
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18C658-I/PT
Manufacturer:
Microchip
Quantity:
601
Part Number:
PIC18C658-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18C658T-E/L
Manufacturer:
Microchip Technology
Quantity:
10 000
PIC18CXX8
15.4.4.1
The master device generates all of the serial clock
pulses and the START and STOP conditions. A trans-
fer is ended with a STOP condition or with a Repeated
START condition. Since the Repeated START condi-
tion is also the beginning of the next serial transfer, the
I
In Master Transmitter mode, serial data is output
through SDA, while SCL outputs the serial clock. The
first byte transmitted contains the slave address of the
receiving device (7 bits) and the Read/Write (R/W) bit.
In this case, the R/W bit will be logic ’0’. Serial data is
transmitted eight bits at a time. After each byte is trans-
mitted, an Acknowledge bit is received. START and
STOP conditions are output to indicate the beginning
and the end of a serial transfer.
In Master Receive mode, the first byte transmitted con-
tains the slave address of the transmitting device
(7 bits) and the R/W bit. In this case, the R/W bit will be
logic ’1’. Thus, the first byte transmitted is a 7-bit slave
address followed by a ’1’ to indicate receive bit. Serial
data is received via SDA, while SCL outputs the serial
clock. Serial data is received eight bits at a time. After
each byte is received, an Acknowledge bit is transmit-
ted. START and STOP conditions indicate the begin-
ning and end of transmission.
The baud rate generator used for the SPI mode opera-
tion is now used to set the SCL clock frequency for
either 100 kHz, 400 kHz, or 1 MHz I
baud rate generator reload value is contained in the
lower 7 bits of the SSPADD register. The baud rate
generator will automatically begin counting on a write to
the SSPBUF. Once the given operation is complete
(i.e., transmission of the last data bit is followed by
ACK), the internal clock will automatically stop counting
and the SCL pin will remain in its last state.
DS30475A-page 152
2
C bus will not be released.
I
2
C Master Mode Operation
2
C operation. The
Advanced Information
A typical transmit sequence would go as follows:
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
The user generates a START condition by set-
ting the START Enable (SEN) bit (SSPCON2
register).
SSPIF is set. The MSSP module will wait the
required start time before any other operation
takes place.
The user loads the SSPBUF with the address to
transmit.
Address is shifted out the SDA pin until all eight
bits are transmitted.
The MSSP module shifts in the ACK bit from the
slave device and writes its value into the
ACKSTAT bit (SSPCON2 register).
The MSSP module generates an interrupt at the
end of the ninth clock cycle by setting the SSPIF
bit.
The user loads the SSPBUF with eight bits of
data.
Data is shifted out the SDA pin until all eight bits
are transmitted.
The MSSP module shifts in the ACK bit from the
slave device and writes its value into the
ACKSTAT bit (SSPCON2 register).
The MSSP module generates an interrupt at the
end of the ninth clock cycle by setting the SSPIF
bit.
The user generates a STOP condition by setting
the STOP Enable bit PEN (SSPCON2 register).
Interrupt is generated once the STOP condition
is complete.
 2000 Microchip Technology Inc.