AT89C51RE2 Atmel Corporation, AT89C51RE2 Datasheet - Page 93

no-image

AT89C51RE2

Manufacturer Part Number
AT89C51RE2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51RE2

Flash (kbytes)
128 Kbytes
Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
34
Spi
1
Uart
2
Sram (kbytes)
8.25
Self Program Memory
API
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Isp
UART/OCD
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51RE2-RLTEM
Manufacturer:
BPS
Quantity:
30 000
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
MSC
Quantity:
1 560
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
759
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
HONEYWELL
Quantity:
101
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
AT89C51RE2-SLSUM
Quantity:
3 800
Part Number:
AT89C51RE2-UM
Manufacturer:
XILINX
Quantity:
101
PCA Watchdog
Timer
7663E–8051–10/08
Figure 35. PCA PWM Mode
An on-board watchdog timer is available with the PCA to improve the reliability of the system
without increasing chip count. Watchdog timers are useful for systems that are susceptible to
noise, power glitches, or electrostatic discharge. Module 4 is the only PCA module that can be
programmed as a watchdog. However, this module can still be used for other modes if the
watchdog is not needed. Figure 33 shows a diagram of how the watchdog works. The user pre-
loads a 16-bit value in the compare registers. Just like the other compare modes, this 16-bit
value is compared to the PCA timer value. If a match is allowed to occur, an internal reset will be
generated. This will not cause the RST pin to be driven high.
In order to hold off the reset, the user has three options:
1. periodically change the compare value so it will never match the PCA timer,
2. periodically change the PCA timer value so it will never match the compare values, or
3. disable the watchdog by clearing the WDTE bit before a match occurs and then re-enable it.
The first two options are more reliable because the watchdog timer is never disabled as in option
#3. If the program counter ever goes astray, a match will eventually occur and cause an internal
reset. The second option is also not recommended if other PCA modules are being used.
Remember, the PCA timer is the time base for all modules; changing the time base for other
modules would not be a good idea. Thus, in most applications the first solution is the best option.
This watchdog timer won’t generate a reset out on the reset pin.
ECOMn
CAPPn
Enable
CAPNn MATn TOGn PWMn ECCFn
Overflow
PCA counter/timer
8 bit comparator
CCAPnH
CCAPnL
CL
CCAPMn, n= 0 to 4
0xDA to 0xDE
“1”
“0”
AT89C51RE2
CEXn
93

Related parts for AT89C51RE2