AT89C51RE2 Atmel Corporation, AT89C51RE2 Datasheet - Page 124

no-image

AT89C51RE2

Manufacturer Part Number
AT89C51RE2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51RE2

Flash (kbytes)
128 Kbytes
Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
34
Spi
1
Uart
2
Sram (kbytes)
8.25
Self Program Memory
API
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Isp
UART/OCD
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51RE2-RLTEM
Manufacturer:
BPS
Quantity:
30 000
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
MSC
Quantity:
1 560
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
759
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
HONEYWELL
Quantity:
101
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
AT89C51RE2-SLSUM
Quantity:
3 800
Part Number:
AT89C51RE2-UM
Manufacturer:
XILINX
Quantity:
101
Hardware
Watchdog
Timer
Using the WDT
124
AT89C51RE2
The WDT is intended as a recovery method in situations where the CPU may be subjected to
software upset. The WDT consists of a 14-bit counter and the WatchDog Timer ReSeT
(WDTRST) SFR. The WDT is by default disabled from exiting reset. To enable the WDT, user
must write 01EH and 0E1H in sequence to the WDTRST, SFR location 0A6H. When WDT is
enabled, it will increment every machine cycle while the oscillator is running and there is no way
to disable the WDT except through reset (either hardware reset or WDT overflow reset). When
WDT overflows, it will drive an output RESET HIGH pulse at the RST-pin.
To enable the WDT, user must write 01EH and 0E1H in sequence to the WDTRST, SFR loca-
tion 0A6H. When WDT is enabled, the user needs to service it by writing to 01EH and 0E1H to
WDTRST to avoid WDT overflow. The 14-bit counter overflows when it reaches 16383 (3FFFH)
and this will reset the device. When WDT is enabled, it will increment every machine cycle while
the oscillator is running. This means the user must reset the WDT at least every 16383 machine
cycle. To reset the WDT the user must write 01EH and 0E1H to WDTRST. WDTRST is a write
only register. The WDT counter cannot be read or written. When WDT overflows, it will generate
an output RESET pulse at the RST-pin. The RESET pulse duration is 96 x T
T
tions of code that will periodically be executed within the time required to prevent a WDT reset.
To have a more powerful WDT, a 2
ranking from 16ms to 2s @ F
description, Table 92.
Table 92. WDTRST Register
WDTRST - Watchdog Reset Register (0A6h)
Reset Value = XXXX XXXXb
Write only, this SFR is used to reset/enable the WDT by writing 01EH then 0E1H in sequence.
CLK PERIPH
7
-
= 1/F
CLK PERIPH
6
-
. To make the best use of the WDT, it should be serviced in those sec-
OSCA
5
-
= 12MHz. To manage this feature, refer to WDTPRG register
7
counter has been added to extend the Time-out capability,
4
-
3
-
2
-
1
-
CLK PERIPH
7663E–8051–10/08
, where
0
-

Related parts for AT89C51RE2