AT89C51RE2 Atmel Corporation, AT89C51RE2 Datasheet - Page 80

no-image

AT89C51RE2

Manufacturer Part Number
AT89C51RE2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51RE2

Flash (kbytes)
128 Kbytes
Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
34
Spi
1
Uart
2
Sram (kbytes)
8.25
Self Program Memory
API
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Isp
UART/OCD
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51RE2-RLTEM
Manufacturer:
BPS
Quantity:
30 000
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
MSC
Quantity:
1 560
Part Number:
AT89C51RE2-RLTUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
759
Part Number:
AT89C51RE2-SLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
HONEYWELL
Quantity:
101
Part Number:
AT89C51RE2-SLSUM
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
AT89C51RE2-SLSUM
Quantity:
3 800
Part Number:
AT89C51RE2-UM
Manufacturer:
XILINX
Quantity:
101
Registers
80
AT89C51RE2
Table 52. T2CON Register
T2CON - Timer 2 Control Register (C8h)
Reset Value = 0000 0000b
Bit addressable
Number
TF2
Bit
7
7
6
5
4
3
2
1
0
Mnemonic
CP/RL2#
EXEN2
EXF2
RCLK
C/T2#
EXF2
TCLK
TR2
Bit
TF2
6
Description
Timer 2 overflow Flag
Timer 2 External Flag
Set when a capture or a reload is caused by a negative transition on T2EX pin if
EXEN2=1.
When set, causes the CPU to vector to Timer 2 interrupt routine when Timer 2 interrupt
is enabled.
Must be cleared by software. EXF2 doesn’t cause an interrupt in Up/down counter mode
(DCEN = 1).
Receive Clock bit
Cleared to use timer 1 overflow as receive clock for serial port in mode 1 or 3.
Set to use Timer 2 overflow as receive clock for serial port in mode 1 or 3.
Transmit Clock bit
Cleared to use timer 1 overflow as transmit clock for serial port in mode 1 or 3.
Set to use Timer 2 overflow as transmit clock for serial port in mode 1 or 3.
Timer 2 External Enable bit
Cleared to ignore events on T2EX pin for Timer 2 operation.
Set to cause a capture or reload when a negative transition on T2EX pin is detected, if
Timer 2 is not used to clock the serial port.
Timer 2 Run control bit
Cleared to turn off Timer 2.
Set to turn on Timer 2.
Timer/Counter 2 select bit
Cleared for timer operation (input from internal clock system: F
Set for counter operation (input from T2 input pin, falling edge trigger). Must be 0 for
clock out mode.
Timer 2 Capture/Reload bit
If RCLK=1 or TCLK=1, CP/RL2# is ignored and timer is forced to auto-reload on Timer 2
overflow.
Cleared to auto-reload on Timer 2 overflows or negative transitions on T2EX pin if
EXEN2=1.
Set to capture on negative transitions on T2EX pin if EXEN2=1.
RCLK
5
Must be cleared by software.
Set by hardware on Timer 2 overflow, if RCLK = 0 and TCLK = 0.
TCLK
4
EXEN2
3
TR2
2
CLK PERIPH
C/T2#
1
7663E–8051–10/08
).
CP/RL2#
0

Related parts for AT89C51RE2