MC9S12XDT512MAA Freescale, MC9S12XDT512MAA Datasheet - Page 777

no-image

MC9S12XDT512MAA

Manufacturer Part Number
MC9S12XDT512MAA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDT512MAA

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
59
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
80
Package Type
PQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDT512MAA
Manufacturer:
FREESCALE
Quantity:
2 546
Part Number:
MC9S12XDT512MAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDT512MAA
Manufacturer:
FREESCALE
Quantity:
2 546
20.4.5.3.1
The format of the control information byte for both S12XCPU and XGATE modules is dependent upon
the active trace mode and tracing source as described below. In Normal, Loop1, or Pure PC modes tracing
of XGATE activity, XINF is used to store control information. In Normal, Loop1, or Pure PC modes
tracing of S12XCPU activity, CINF is used to store control information. In Detail Mode, CXINF contains
the control information
XGATE Information Byte
X12X_CPU Information Byte
Freescale Semiconductor
XCOT
XSOT
Field
XSD
XDV
7
6
5
4
Source Destination Indicator — This bit indicates if the corresponding stored address is a source or destination
address. This is only used in Normal and Loop1 mode tracing.
0 Source Address
1 Destination Address or Start of Thread or Continuation of Thread
Source Of Thread Indicator — This bit indicates that the corresponding stored address is a start of thread
address. This is only used in Normal and Loop1 mode tracing.
NOTE. This bit only has effect on devices where the XGATE module supports multiple interrupt levels.
0 Stored address not from a start of thread
1 Stored address from a start of thread
Continuation Of Thread Indicator — This bit indicates that the corresponding stored address is the first
address following a return from a higher priority thread. This is only used in Normal and Loop1 mode tracing.
NOTE. This bit only has effect on devices where the XGATE module supports multiple interrupt levels.
0 Stored address not from a continuation of thread
1 Stored address from a continuation of thread
Data Invalid Indicator — This bit indicates if the trace buffer entry is invalid. It is only used when tracing from
both sources in Normal, Loop1 and Pure PC modes, to indicate that the XGATE trace buffer entry is valid.
0 Trace buffer entry is invalid
1 Trace buffer entry is valid
Information Byte Organization
XSD
CSD
Bit 7
Bit 7
XSOT
Bit 6
Bit 6
CVA
Figure 20-25. S12XCPU Information Byte CINF
Figure 20-24. XGATE Information Byte XINF
Table 20-40. XINF Field Descriptions
XCOT
MC9S12XDP512 Data Sheet, Rev. 2.21
Bit 5
Bit 5
0
Bit 4
Bit 4
CDV
XDV
Description
Bit 3
Bit 3
0
0
Bit 2
Bit 2
0
0
Chapter 20 S12X Debug (S12XDBGV3) Module
Bit 1
Bit 1
0
0
Bit 0
Bit 0
0
0
779