PHAST-12P Device
DATA SHEET
TXC-06412B
PRELIMINARY TXC-06412B-MB, Ed. 2
June 2005
PPUTPTPACLAV3
PPUTPTPACLAV2
PPUTPTPACLAV1
PPUTPTPACLAV0
PPUTRXADDR4
PPUTRXADDR3
PPUTRXADDR2
PPUTRXADDR1
PPUTRXADDR0
PPUTRXCLK
PPTXSPTA
PPTXMOD
PPTXEOP
PPTXERR
Symbol
Symbol
Note: The Transmit UTOPIA Interface and the Transmit POS-PHY Interface share the same
RECEIVE UTOPIA INTERFACE
Lead No.
Lead No.
leads.
G19
A19
A18
B17
C16
E21
C22
F19
C12
B12
A12
C11
A11
B11
I/O/P
O(T)
O(T)
I/O/P
I
I
I
LVCMOS
LVCMOS
-
LVTTL
24mA
24mA
Lead Descriptions
LVTTL
LVTTL
Type
Type
Transmit Cell Available signals: Tristateable signal
indicating that a complete cell can be transferred. Both
direct status and multiplexed status are supported. It is
driven when a matching PHY address is presented on
PPUTTXADDR. Tristated when either the null-PHY
address or a not matching PHY address is presented on
PPUTTXADDR.
UTOPIA Standard notation: TxClav[3:0]
Not Applicable Inputs: These leads must be tied to
VSS.
Not Applicable Output: This lead must be left uncon-
nected.
Receive UTOPIA Clock: This clock is used for the
receive UTOPIA interface. The data and control signals
are transferred on the rising edge of this clock. Maxi-
mum clock frequency is 50 MHz.
UTOPIA Standard notation: RxClk
Receive PHY Address Bus: In multi-PHY mode, these
leads indicate the address of the PHY being selected
and polled. Note that the null-PHY address is not
responded to. In single-PHY mode, this address is not
used and these leads must be tied to VSS.
UTOPIA Standard notation: RxAddr[4:0]
-
Name/Function
Name/Function
3 4 o f 2 26