TXC-06412BIOG Transwitch Corporation, TXC-06412BIOG Datasheet - Page 205

no-image

TXC-06412BIOG

Manufacturer Part Number
TXC-06412BIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-06412BIOG

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TXC-06412BIOG
Manufacturer:
TRANSWITCH
Quantity:
5
2 0 5 o f 2 26
0x000C
0x000A
0x000E
Offset
0x0000
0x0002
0x0004
0x0006
0x0008
Offset
0x0000
0x0002
0x0004
9-0
0
13-0
14-0
0
4 - 0
15 - 0
15 - 0
0
2 - 0
0
Bits
Bits
Table 68: Setup of Clock Recovery/Clock Synthesis/SerDes
TxPowerDown
LineRate
RxPowerDown1
RxPowerDown2
ToplevelPowerDown
OC3NotOC12
PRBSBitErrorCounter
IndirectAccessData
TimingMode
LineTimingChannel
TxRefSelect
Name
Name
- Memory Maps and Bit Descriptions -
Table 69: PLL Control
Init
0x0
0x0
0x0
0x3FFF
0x7FFF
0x3FF
Init
0x1F
External/Line timing mode selection for the transmit PLL.
External timing mode is selected when 0x0, TxRefSelect selects the exter-
nal source.
Line-Timing mode is selected when 0x1, LineTimingChannel selects the line
timing channel.
Range 0 to 4
Line timing mode channel selection.
This field is only used when TimingMode is ‘1’. The value indicates the line.
Transmit reference clock external source selection for the PLL in the trans-
mit section.
This field is only valid when TimingMode is ‘0’.
0x0
0x1
0x0
0x0
0x0: Line 1
0x1: Line 2
0x2: Line 3
0x3: Line 4
0x4: APS
0x0: REFTXCLK1 is used as reference clock
0x1: REFTXClK2 is used as reference clock
Power down for the SerDes transmit section.
Must be set to 0x0 at power-up.
Indicates the line rate for the selected line when line timing is used.
Line rate is 155.52 Mbit/s when 0x0, 622.08 Mbit/s when 0x1.
Note: This setting is only applicable for the line selected by LineTim-
ingChannel when TimingMode is 0x1.
Power down for the SerDes receive section.
Must be set to 0x0 at power-up.
Power down for the SerDes receive section.
Must be set to 0x0 at power-up.
Power down for the toplevel SerDes bias module.
Must be set to 0x0 at power-up.
Line Rate Configuration
Bit Error counter of the PRBS analyzer at the cross connect.
This (read-only) counter is clear-on-read.
Indirect Access Data register. When a write is done to this register,
the field specified by the IndirectAccessMode will be configured.
Following values need to be set when initializing the CDR/CS:
0x0E: STM-4 Mode
0x0F: STM-1 Mode
All others: Reserved
0x0017 to IndirectAccessMode Mode0
0x5000 to IndirectAccessMode Mode1
(T_PLL_Control)
Description
Description
PRELIMINARY TXC-06412B-MB, Ed. 2
(T_CDR_CS_Setup)
PHAST-12P Device
DATA SHEET
TXC-06412B
June 2005