Operation using the mouse (1)
Operation using the mouse (2)
Operation using the menu
4-2-9 Copying an Entire Table
Operation using the mouse (1)
Operation using the mouse (2)
68
Operating the Application Manager
Caution:
Reference: S To start up second Support Tool, select [Import Component] from [File] menu,
(1) Select [Tools] in the menu bar, then choose [Table], [Image Editor], [Library
(2) If [Table] is chosen, select the tab of the table to be edited.
(1) Specify the table data icon.
(2) Click right button of the mouse on the selected table data icon, then select
(3) Click right button of the mouse on the desired table in the table data icon dis-
(4) In the confirmation dialog box, click the
(1) Specify the table data icon.
For details, refer to Section 7 Memory Table Setting or Section 8 Editing Graphic
Data.
Double click the icon of the table data to be edited.
Make a right click on the icon of the table data to be edited, then select [Modify].
An entire table can be copied between the screen data files of the same PT mod-
el by starting up two Support Tools.
Copying of tables, screens, and objects between two screen data files involves
addition or overwriting of PLC address. Please check the movement sufficiently
before shifting to actual operation.
S If the whole table is copied, all the contents in the specified table are copied
S A check box for “Overwrite PLC Address” appears when copying the whole
For details, refer to 3-3-6 Importing Components from Different Screen Data
File (Starting Up the Second Support Tool).
collectively. For method to copy the individual data in a table, refer to Section 7
Memory Table Setting or Section 8 Editing Graphic Data.
table indicated below. If this check box is checked, PLC address setting is over-
written. If not checked, settings such as initial value will be overwritten but the
PLC address setting remains the same. Note that I/O comments are not copied
even if the PLC address is overwritten. If you need the same I/O comment,
copy the I/O comment.
Bit memory table, Extended I/O output table, Numeral table, String table, F-
Key input notify table
Editor] or [Mark Editor].
Multiple tables can be selected by dragging the mouse cursor while pressing
the Shift key or Ctrl key.
[Copy].
play area of another Support Tool, then select [Paste].
“Overwrite PLC Address” appeared in the dialog box, make the setting as
required.
Multiple tables can be selected by dragging the mouse cursor while pressing
the Shift key or Ctrl key.
Button. If a check box for
Section
4-2