NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 483

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Data Conversion
Correction related to extended I/O input/output table
Correction of image codes
S Difference
S Conversion result, error message and corrective action
When an extended I/O input/output table is converted, the data is converted in
the manner shown below due to differences in the handling of an extended I/O
input/output table between NT30/NT30C and other models.
S Difference
S Conversion result, error message and corrective action
When an image code is converted between a conventional and a new model,
conversion is executed in the manner shown below due to differences in the
image codes between them.
S Difference
New models:
Conventional models:
NT30/NT30C:
Other models:
New models:
Conventional models:
[Switch screen]: OFF
[Screen No]: 0
[Switch screen]: OFF
[Screen No]: As desired
[Switch screen]: OFF
[Screen No]: 0
[Switch screen]: ON
[Screen No]: As desired
With an NT30/
NT30C, an ex-
tended I/O input/
output table is set.
Status before
Conversion
Status before
Conversion
With a PT model
other than NT30/
NT30C, the setting
of an extended I/O
input/output table is
discarded.
Function: None
[Switch screen]: OFF
[Screen No]: 0
Function: Alarm
[Switch screen]: ON
[Screen No]: As desired
Function: Alarm
[Switch screen]: ON
[Screen No]: 9999
Function: Alarm
[Switch screen]: ON
[Screen No]: As desired
Status after
Conversion
Alarm function and switch screen function cannot be
set simultaneously.
Alarm function and switch screen function can be set
simultaneously.
Extended I/O input/output table can be used.
Extended I/O input/output table cannot be used.
0001 to 0FFF (hexadecimal)
FE20 to FEFF (hexadecimal)
Status after
Conversion
Error Message
Message
––
Error
––
––
––
––
Change function to
[Alarm], if you want to dis-
play the alarm. (Refer to
7-4 Bit Memory Table.)
Correction is not neces-
sary.
Correction is not neces-
sary.
Change the function to
[Switch screen]. (Refer to
7-4 Bit Memory Table.)
Correct the screen data
and a host program so
that unusable table
entries can be replaced
with inputs/outputs of a
host, etc. (Refer to 7-5
Extended I/O Input
Table and 7-6 Extended
I/O Output Table.)
Corrective Action
Corrective Action
Appendix A
471

Related parts for NT600SST121BEV3