NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 473

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Direct Access Types
Conversion between different direct accesses (PLC vendor)
Reference: S The direct access version that can be handled by the Support Tool is:
This section describes the data conversion method between different direct ac-
cess types and different PT models.
In the following explanation, the NT20S, NT30, NT30C, NT600S, NT620S,
NT620C, and NT625C are referred to as “conventional models” and the NT21,
NT31, NT31C, NT631, and NT631C (including models with “-V1,” “-V1 (System
Ver. 2.1)” and “-V2 (System Ver.3.1)”) are referred to as “new models.”
Direct access type can be set at “PLC Vendor” of “PT Type (PT Configuration).”
Changing PLC vendor of existing screen data changes direct access type.
The direct access types that can be handled by the Support Tool (Ver. 3.j) are as
follows;
OMRON:
Memory Link:
Mitsubishi A:
Mitsubishi FX:
Memory Link, Mitsubishi A and Mitsubishi FX can be set only with NT31, NT31C,
NT631 and NT631C with “-V1” and above.
S Depending on the direct access types, exclusive system program may be
S To create screen data to be used for direct access (PLC vendor) other than
With the Support Tool (Ver. 4.1), data conversion between different direct ac-
cesses such as OMRON Mitsubishi A or Mitsubishi FX OMRON is possible.
However, data conversion between different direct accesses is limited to data of
the same PT model. (e.g., Between NT31-V1 data for OMRON and Mitsubishi A)
When both direct accesses and PT model are different, convert data to that of the
same PT model first (see figures in next page) and then convert the direct access
type.
NT20S, NT600S: Ver. 5
Conventional models other than NT20S, NT600S: Ver. 4
New models: No direct access versions
needed for the PT hardware.
For details of the system programs and system installer, refer to Appendix B
System Installer Operation.
OMRON, Memory Link, Mitsubishi A and Mitsubishi FX, use system installer of
DOS version.
Data Conversion
Appendix A
This is a direct access for OMRON PLCs
This is a simulative direct access with which host and PT
execute sending or receiving of command via RS-232C/422A
communication.
This is a direct access for Mitsubishi A series PLC.
This is a direct access for Mitsubishi FX series PLC.
461