NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 174

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Guidance
162
Alarm
Reference: With NT31, NT31C, NT631, NT631C, if image/library data is larger than the
(1) Specify only the image/library data display area (dotted line frame) while
(2) Specify the display size of the image/library data display area and move it as
S Using a line scroll touch switch and a page scroll touch switch, you can scroll
S With NT31, NT31C, NT631, and NT631C, to display a line scroll touch switch
S With the NT21, NT31, NT31C, NT631, and NT631C, a line scroll touch switch
S To display the image/library data, set a check mark in the check box of [Display
S The procedure for editing the image/library data display area is shown below.
S If the size of the image/library data is smaller than the display area, the image/
image/library data display area, the area exceeding the display area will not be
Start Bit Table Entry:
No. of Bits Referenced: Specify the number of bit memory table entries that
messages in units of a line or a page within the alarm list display area.
and/or a page scroll touch switch, set a check mark in the line scroll touch
switch and/or a page scroll touch switch check box in the Property setting dia-
log box.
and a page scroll touch switch are a part of an alarm list element. Therefore,
they cannot be modified as a touch switch. They can be moved only when the
alarm list is modified. For the NT21, NT31, NT31C, NT631, and NT631C, the
line and page scroll touch switch can be moved by clicking the desired touch
switch while holding down the Shift key and Ctrl key. ([Edit Object] from the
[Edit] menu (or pop-up menu) and Ins key can also be used for this operation.)
With NT30, NT30C, NT620S, NT620C, and NT625C, however, a line scroll
touch switch and a page scroll touch switch are independent elements and
their position, size, and label can be changed as required. However, the touch
switch function and the lamp setting should not be changed, otherwise the
switch and the lamp will fail to function correctly on PT.
Image Lib] in the Property setting dialog box.
library data is displayed taking the lower left corner of the display area as the
reference.
holding down the Shift key and Ctrl key. (automatically enters to Edit Object
mode)
Green J marks (handles) are displayed surrounding the image/library data
display area.
There are other methods to enter Edit Object mode. For details, refer to
Specifying an element consisting of multiple elements on page 108.
desired.
Image/library data display area
Image/library data
Specify the start number of bit memory table entries
that are checked by the alarm list element.
are checked by the alarm list element.
Section
6-3