NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 493

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Data Conversion
Correction related to sampling cycles of trend graphs
Correction related to the 100% value, 0% value and –100% value of a graph
S Conversion result, error message and corrective action
In the conversion of the data between a conventional and a new model, conver-
sion is executed in the manner shown below due to differences of trend graph
sampling cycles.
S Difference
S Conversion result, error message and corrective action
In the conversion of the data between a conventional and a new model, conver-
sion is executed in the manner shown below due to differences in the range of
numeral that can be input.
S Difference
New models:
Conventional models:
New models:
With a conventional
model, the marks
with codes FFEF to
FFF5 are used as
desired.
With a conventional
model, the marks
with codes FFEF to
FFF5 are not used.
With a conventional
model, the sampling
cycle is set in units
other than 0.5 s.
Status before
Status before
Conversion
Conversion
With a new model,
marks registered
with a conventional
model are used as
trend graph control
touch switches.
With a new model,
nothing is registered
for codes FFEF to
FFF5 and trend
graph control touch
switches are not
displayed.
With a new model,
the sampling cycle
is corrected to 0.5 s
unit cycle (corrected
to the nearest val-
ue).
Status after
Status after
Conversion
Conversion
The sampling cycle can be set in the range from 0.5 to
The sampling cycle can be set in the range from 0.1 to
A numeric value of up to 10 digits can be input for a %
6553.5 s in units of 0.5 s.
6553.5 s in units of 0.1 s.
value.
[W]
Sampling cycle less
than minimum val-
ue. Minimum value
restored.
[W]
Sampling cycle not
multiple of 5. Value
rounded off to near-
est multiple of 5.
Error Message
Error Message
––
––
(1) Copy marks regis-
(2) Reset the marks
(3) For the elements
Reset the marks with
codes FFEF to FFF5
with the mark editor. The
marks of these codes
are recognized as the
trend graph control
marks. (Refer to 8-3
Mark Editor.)
Since there are no prob-
lems in actual operation,
correction is not neces-
sary.
Corrective Action
Corrective Action
tered under codes
FFEF to FFF5 to
other codes with the
mark editor.
with codes FFEF to
FFF5 with the mark
editor. (By resetting,
the marks are re-
turned to the trend
graph control
marks.)
that use the conven-
tional marks of
codes FFEF to
FFF5, correct the
codes to those as-
signed after copying
the marks. (Refer to
8-3 Mark Editor.)
Appendix A
481