7-4-3 Description of Bit Memory Table Fields
Items set to use the screen switching function
288
Bit Memory Table
As the reference of bit memory table setting, please refer to 6-3 Alarm.
To use the screen switching function, follow the procedure below.
(1) Input PLC address directly on a PLC address field on a bit memory table
(2) Click on
(3) Select “Switch Screen” from function combo box.
(4) Set screen number to be switched for “Screen No..”
S Settings to make at the Set dialog
PLC Address
Specify the bit in a PC (PLC) whose status is reflected by the bit memory table
entry.
I/O Comment
Specify a comment for a PC (PLC) bit.
A comment can comprise up to 16 characters.
S Settings to make at the Function dialog
Function
Select [Alarm/Switch Screen] for NT30, NT30C, NT620S, NT620C, and
NT625C, and select [Switch Screen] for the NT21, NT31, NT31C, NT631, and
NT631C.
When converting the bit memory table from NT30, NT30C,
NT620S, NT620C, NT625C to NT31, NT31C, NT631, NT631C,
the function setting is not the same with before converting. To
adjust the setting of this bit memory table, please refer to Data
Conversion (Bit memory conversion) in Appendix A.
entry or click on
log. (Refer to Word setting for an element on page 127). Input I/O comment if
required.
Setting items for screen switching function are displayed.
WARNING
to display function dialog.
and input PLC address on a PLC address dia-