NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 481

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Data Conversion
Correction related to extended screens
Correction related to history screens
Correction related to the number of memory tables
S Conversion result, error message and corrective action
When an extended screen is converted, an error message may be displayed due
to differences in the handling of an extended screen between conventional and
new models.
S Difference
S Conversion result, error message and corrective action
When a history screen is converted, an error message may be displayed due to
differences in the handling of the screen numbers of the frequency history screen
and the occurrence history screen between conventional and new models.
S Difference:
S Conversion result, error message and corrective action
Since the number of entries that can be used in the memory tables depend on the
PT model, conversion is executed in the manner shown below.
New models:
Conventional models:
New models:
Conventional models:
With a conventional
model, elements
that cannot be reg-
istered on a new
model are regis-
tered.
With a conventional
model, the screen
number of an ex-
tended screen is
used for a standard
screen.
With a conventional
model, a history
screen (occurrence
order, frequency or-
der) is edited.
Status before
Status before
Status before
Conversion
Conversion
Conversion
With a new model,
the screen No. is
modified to 9000.
Elements that can-
not be registered for
a new model are re-
moved.
With a new model,
the screen is
treated as a stan-
dard screen.
With a new model,
the history screen is
deleted (displaying
the edited history
screen is possible
by specifying it from
a PT).
Status after
Status after
Status after
Conversion
Conversion
Conversion
Extended screens are not supported.
Extended screens can be used as standard screens.
Screen No. 9001 and No. 9002
Screen No. 1997 and No. 1998
History screens (occurrence order, frequency order)
cannot be edited.
History screens (occurrence order, frequency order)
can be edited.
This screen does
not support XXX. It
is discarded.
The screen no. XXX
was an Extended
Screen that is not
supported by this
model, so it is con-
verted to a standard
screen.
The screen no. xxx
was a history occur-
rence (frequency)
screen that is not
supported in this
model. It is dis-
carded.
Error Message
Error Message
Error Message
Correct the screen so
that the same screen as
before the conversion is
created using fixed dis-
play elements excluding
image/library data. (Re-
fer to 5-8. Host Connect
Screen (System Initializ-
ing Screen))
Corrective Action
Corrective Action
Corrective Action
Appendix A
––
––
469