Correcting the PC (PLC) addresses (On data conversion between PT models)
Correction related to continuous screens
466
S Conversion result, error message and corrective action.
When converting the data of the entire screen data file, screen data for use with
new models cannot be converted to screen data for use with conventional mod-
els. However, if the data of a new model is registered for the screen of a conven-
tional model using the symbol manager, the following points must be taken into
consideration due to differences in the usable PC (PLC) address range between
a conventional and a new model.
S Difference
S Conversion result, error message and corrective action
When the data of a conventional model is converted into data for a new model, an
error may occur due to differences in the handling of continuous screens be-
tween conventional models and new models.
S Difference
New models:
Conventional models:
New models:
Conventional models:
With OMRON data,
an area other than
the CIO area is set.
With a new model,
word addresses are
within four digits.
With a new model,
the word address is
five digits.
Status before
Status before
Conversion
Conversion
The PLC address is
reset.
With a conventional
model, word
addresses remain
as they were.
The word address is
reset.
Status after
Status after
Conversion
Conversion
Word addresses can be handled up to five digits.
Word addresses can be handled up to four digits.
Continuous screens cannot be used.
Continuous screens can be used.
PLC address (XXX)
of YYY is invalid. It
is reset to default.
Invalid PC (PLC)
address. It is reset
to default.
Error Message
Error Message
––
Reset the area to
memory link area (PT
memory). If this PC
(PLC) address is re-
ferred to from the pro-
gram, it is necessary to
correct the program ac-
cordingly. (Refer to
6-1-10 Setting Proper-
ties.)
Reset the word address
to a number of four or
less digits. If this PC
(PLC) address is re-
ferred to from the pro-
gram, it is necessary to
correct the program ac-
cordingly. (Refer to
6-1-10 Setting Proper-
ties.)
Corrective Action
Corrective Action
Appendix A
––