NT600SST121BEV3 Omron, NT600SST121BEV3 Datasheet - Page 429

no-image

NT600SST121BEV3

Manufacturer Part Number
NT600SST121BEV3
Description
LCD Touch Panels
Manufacturer
Omron
Datasheet

Specifications of NT600SST121BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
NT600S-ST121B-EV3
Quick Reference
Writing
Data to
the PC
(PLC)
Writing
Data to
the PC
(PLC)
[To write a character
string]
To copy between charac-
ter string memory table
entries (string table) with
one touch switch
To disable the input ac-
cording to the ON/OFF
status of a PC(PLC) bit
To store calculated result
in numeral table entry
To store calculated result
in a specified PLC ad-
dress
To store more than one
value in a specified PLC
address
Item
(1) [Objects] – [Touch Switch] – [Function: Copy Setting]
(2) [Objects] – [String Display]
(1) [Objects]
(2) Turn OFF the PC (PLC) bit to which the interlock is
(1) [Tools] – [Mathematical Table]
Click on Set button to specify the formula for calculation and
set result to specific Numeral table entry.
(1) [Tool] – [Mathematical Table]
Click on Set button to specify the formula for calculation and
set result to specific plc address.
(1) [Tools] – [Recipe Table]
Create Recipe entry.
(2) [Objects] – [Data Input] – [Recipe]
Create Recipe object referring to the Recipe entry. In Settings
properties, check Show Window/Keyboard Screen and set
screen number to display keypad. Create window screen con-
taining keypad.
(Only for NT21, NT31/631-V2 and above)
It is possible to disable the input into a data input object by
using Numeral/Character string input flag in PT status con-
trol bits.
(Except NT20S and NT600S)
Create a touch switch for which the copy function is set,
and copy the content of a character string memory table
entry (string table) to another character string memory
table entry (string table).
Display the content of the character string memory table
entry (string table).
or [Thumbwheel Switch]
Create a data input object and set Interlock on.
allocated to disable from inputting.
PT
Screen
Input
Numeral setting input field
*
7
4
PT
123
Screen
Q
8
5
2
.
[Data Input]
9 +–
6
3
Touch switch (control code input),
or system keypad
ABC
Touch switch (copy function)
Numeral
memory
table
Operation
123
Character string display
Disable the input
Character string
memory table
(String table)
[Numeral],[String],[Recipe]
ABC
ABC
Î Î
PC (PLC)
Bit
Section
Refer to
6-1-12
6-11-1
6-8-6
7-10
6-7
7-9
7-9
10-1
417