D13002F16V Renesas Electronics America, D13002F16V Datasheet - Page 68

IC H8/3002 ROMLESS 100QFP

D13002F16V

Manufacturer Part Number
D13002F16V
Description
IC H8/3002 ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of D13002F16V

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, PWM, WDT
Number Of I /o
38
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D13002F16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
2.8.4 Exception-Handling Sequences
Reset Exception Handling: Reset exception handling has the highest priority. The reset state is
entered when the
changes from low to high. When reset exception handling starts the CPU fetches a start address
from the exception vector table and starts program execution from that address. All interrupts,
including NMI, are disabled during the reset exception-handling sequence and immediately after it
ends.
Interrupt Exception Handling and Trap Instruction Exception Handling: When these
exception-handling sequences begin, the CPU references the stack pointer (ER7) and pushes the
program counter and condition code register on the stack. Next, if the UE bit in the system control
register (SYSCR) is set to 1, the CPU sets the I bit in the condition code register to 1. If the UE bit
is cleared to 0, the CPU sets both the I bit and the UI bit in the condition code register to 1. Then
the CPU fetches a start address from the exception vector table and execution branches to that
address.
Figure 2-14 shows the stack after the exception-handling sequence.
SP (ER7)
Legend
CCR:
SP:
Notes: 1.
SP–4
SP–3
SP–2
SP–1
Condition code register
Stack pointer
2.
PC is the address of the first instruction executed after the return from the
exception-handling routine.
Registers must be saved and restored by word access or longword access,
starting at an even address.
RES signal goes low. Reset exception handling starts after that, when RES
Figure 2-14 Stack Structure after Exception Handling
Before exception
handling starts
Stack area
Pushed on stack
SP (ER7)
51
SP+1
SP+2
SP+3
SP+4
After exception
handling ends
CCR
PC
Even
address