D13002F16V Renesas Electronics America, D13002F16V Datasheet - Page 477

IC H8/3002 ROMLESS 100QFP

D13002F16V

Manufacturer Part Number
D13002F16V
Description
IC H8/3002 ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of D13002F16V

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, PWM, WDT
Number Of I /o
38
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D13002F16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Receiving Multiprocessor Serial Data: Figure 13-12 shows a sample flowchart for receiving
multiprocessor serial data and indicates the procedure to follow.
No
No
No
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data from RDR
Read receive data from RDR
Figure 13-12 Sample Flowchart for Receiving Multiprocessor Serial Data (1)
Set MPIE bit to 1 in SCR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
Read RDRF flag in SSR
Finished receiving?
FER
FER
Start receiving
RDRF = 1?
RDRF = 1?
Own ID?
Initialize
End
ORER = 1
ORER = 1
No
Yes
Yes
No
Yes
Yes
Yes
Yes
1
2
3
No
(continued on next page)
Error handling
4
461
5
1.
2.
3.
4.
5.
SCI initialization: the receive data function
of the RxD pin is selected automatically.
ID receive cycle: set the MPIE bit to 1 in SCR.
SCI status check and ID check: read SSR,
check that the RDRF flag is set to 1, then read
data from RDR and compare with the
processor’s own ID. If the ID does not match,
set the MPIE bit to 1 again and clear the
RDRF flag to 0. If the ID matches, clear the
RDRF flag to 0.
SCI status check and data receiving: read
SSR, check that the RDRF flag is set to 1,
then read data from RDR.
Receive error handling and break detection:
if a receive error occurs, read the
ORER and FER flags in SSR to identify the error.
After executing the necessary error handling,
clear the ORER and FER flags both to 0.
Receiving cannot resume while either the ORER
or FER flag remains set to 1. When a framing
error occurs, the RxD pin can be read to detect
the break state.

Related parts for D13002F16V