M3062PT3-RPD-E Renesas Electronics America, M3062PT3-RPD-E Datasheet - Page 97

no-image

M3062PT3-RPD-E

Manufacturer Part Number
M3062PT3-RPD-E
Description
EMULATOR BASE UNIT FOR M16C/60
Manufacturer
Renesas Electronics America
Datasheet

Specifications of M3062PT3-RPD-E

Accessory Type
Emulation Pod
For Use With/related Products
PC4701, M16C/60, M16C/30
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
M3062PT3-RPD#E
M3062PT3-RPD#E
REJ10J0040-0600 Rev.6.00 July 01, 2006
M3062PT3-RPD-E User’s Manual
Note on Breaks:
Notes on Software Breaks:
Note on Power Supply to the User System:
Notes on Address-Match Interrupts:
Note on Accessing Addresses 00000h and 00001h:
Note on Debugging Operations After Releasing a Reset from the Target:
The area displaying break points in the program window of the emulator debugger shows the following
breaks.
Software breaks change the instruction at a specified address to a BRK (00h). Therefore, take note that when
you reference the result of a trace in bus mode, "00h" is displayed.
The BRK instruction can be used for the emulator only. You cannot use it in a user program.
It is not possible to use a software break and a hardware break at the same time. If doing so, it may not
operate normally.
In the area where the MAP setting is EXTERNAL, software breaks cannot be used.
Pins Vcc1 and Vcc2 are connected to the user system to observe the voltage. Therefore, the power is not
supplied to the user system from the emulator, design your system so that the user system is powered
separately.
To debug address-match interrupts, set a software break or hardware break at the top address of the
address-match interrupt process. If you set a software break or hardware break at an address where an
address-match interrupt occurs, the program may run out of control.
When an address at which an address-match interrupt occurs is executed in single-step mode, the program
stops after executing the first instruction after returning from the address-match interrupt processing.
With this product, the yellow LED lights when address 00000h is read out by a process other than an
interrupt. However, because the LED is turned off by other than the reset switch of the emulator main unit,
accessing address 00000h can not be detected properly.
Therefore, to detect that address 00000h is read out by a process other than an interrupt, enable a hardware
breakpoint, and using an event, check the program with the following settings.
Do not execute debugging operations such as setting a software or hardware break, runtime debugging after
releasing a reset from the user system until an interrupt stack pointer (ISP) is set in the user program.
(1) Software break
(2) Hardware break
(1) The voltage of the user system should be within the operating range of the evaluation MCU.
(2) Do not change the voltage of the user system after turning on the power.
- Event type: DATA ACCESS
- Address: Range: (addr) == Address1, Address1: 00000h
- Data: Range: Not Specify, Access : READ
This is a debugging function which generates a BRK interruption by changing an instruction at a
specified address to a BRK instruction (00h) to break a program immediately before the system executes
an instruction at a specified address. The instruction at the preset address will not be executed.
This is a debugging function which breaks a program by setting the detection of an execution of an
instruction at a specified address as a break event. The program will break after the instruction at the
specified address is executed.
IMPORTANT
4. Hardware Specifications
Page 95 of 104

Related parts for M3062PT3-RPD-E