M3062PT3-RPD-E User’s Manual
2.5 Turning ON the Power
2.5.1 Checking the Connections of the Emulator System
Before turning the power ON, check the connection of the interface cable with host machine, PC4701, emulation pod, and user
system.
2.5.2 Turning ON/OFF the Power
Turn ON the power of the emulator and user system as simultaneously as possible. Turn OFF the power of the emulator and
user system as simultaneously as possible.
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be damaged.
When turning ON the power again after shutting OFF the power, wait for about 10 seconds.
Notes on Power Supply:
The emulator's pin Vcc is connected to the user system in order to monitor user system voltage. For this reason,
the emulator cannot supply power to the user system. Therefore, provide the user system with a separate power
supply from that of the emulator.
Keep user system power supply voltage within the following range.
Do not change user system power supply voltage after power has been activated.
(1) When the JP1 of the M30620T3-PRT is set as Vcc1 = Vcc2
(2) When the JP1 of the M30620T3-PRT is set as Vcc1 > Vcc2
2.7[V] ≤ Vcc1 = Vcc2 ≤ 5.5[V]
4.8[V] ≤ Vcc1≤ 5.2[V]
2.7[V] ≤ Vcc2 < Vcc1
IMPORTANT
Page 25 of 104
2. Setup

Related parts for M3062PT3-RPD-E