2.5.3 LED Display When the Emulator Starts Up Normally
Figure 2.4 shows front panel LED lighting status when the emulator started up properly. Check it when starting up the
emulator system.
Figure 2.4 LED display when the power turned on
Note on the Target Status POWER LED:
Notes on the Target Status CLOCK LED:
If the MCU has two or more Vcc terminals, the LED does not light unless power is supplied to all the
terminals.
CLOCK LED is turned off when both main and sub clocks are not oscillating. If either clock is oscillating, the
LED is turned on.
If the LED is not turned on, check the following.
(1) After powering on the PC4701 (before starting up the emulator debugger):
(2) After the emulator debugger is started up (after the Init dialog box settings are complete):
Make sure that the oscillator circuit board is properly installed in the PC4701 and it is oscillating normally.
Make sure that the oscillator selected in the Init dialog box is oscillating normally.
LED display when the emulator starts up normally
PERFORMANCE
POWER
ERROR
STATUS OF
SAFE
RESET
EMULATOR
SYSTEM
HIGH
IMPORTANT
POWER
CLOCK
RESET
RUN
HALT
STATUS OF
TARGET
This does not light when the user
system is not connected.
: On
: Off
Page 26 of 104
2. Setup