M3062PT3-RPD-E Renesas Electronics America, M3062PT3-RPD-E Datasheet - Page 68

no-image

M3062PT3-RPD-E

Manufacturer Part Number
M3062PT3-RPD-E
Description
EMULATOR BASE UNIT FOR M16C/60
Manufacturer
Renesas Electronics America
Datasheet

Specifications of M3062PT3-RPD-E

Accessory Type
Emulation Pod
For Use With/related Products
PC4701, M16C/60, M16C/30
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
M3062PT3-RPD#E
M3062PT3-RPD#E
REJ10J0040-0600 Rev.6.00 July 01, 2006
M3062PT3-RPD-E User’s Manual
3) Example Data Settings
(4) Setting the combinatorial event condition for the hardware break point
1) Window for setting the combinatorial event condition
Setting events for wordwise accesses to the even-addresses
STE.W A0,20E8h(A0=5423h)
High-order and low-order data effective
Setting events for wordwise accesses to the odd-addresses
STE.W A0,20E5h(A0=AB79h)
Odd-address high-order data effective
Even-address low-order data effective
Setting events for bytewise accesses to the even-addresses
STE.B R0L,[A1A0](R0L=E5h,A1=0000h,A0=20E2h)
Low-order data effective
Setting events for bytewise accesses to the odd-addresses
STE.B R0L,[A1A0](R0L=E6h,A1=0000h,A0=20E3h)
High-order data effective
Setting a break event
A1
Address 1 :0020E8
Data 1
MASK
Access
Setting a break event
A1
Address 1 :0020E5
Data 1
MASK
Access
Setting a break event
A1
Address 1 :0020E2
Data 1
MASK
Access
Setting a break event
A1
Address 1 :0020E3
Data 1
MASK
Access
Setting the combinatorial event condition
There are following four conditions that you can choose for the
combinatorial events.
- AND
- AND (Same Time)
- OR
- STATE TRANSITION
For each event, a pass count (number of passing) is specifiable
(1--255). When “AND” (same time) is specified for Combination,
you can not specify the pass count (fixed to one).
When you have finished setting the combinatorial event
condition, click the “Set” button.
3. Usage (How to Use the Emulator Debugger)
The program breaks when all of the specified events occur.
The program breaks when the specified events occur at the
same time.
The program breaks when one of the specified events occurs.
The program breaks when the state transition diagram goes
into the break state.
:5423
:FFFF
:WRITE
:AB79
:FFFF
:WRITE
:00E5
:00FF
:WRITE
: 00E6
: 00FF
:WRITE
.
Page 66 of 104