HD6412350 Hitachi, HD6412350 Datasheet - Page 595

no-image

HD6412350

Manufacturer Part Number
HD6412350
Description
(HD6412350 / HD6432351) 16-BIT MICROCONTROLLER
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412350F10
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20
Manufacturer:
RENESAS
Quantity:
648
Part Number:
HD6412350F20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20
Manufacturer:
ST
0
Part Number:
HD6412350F20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS
Quantity:
586
Part Number:
HD6412350F20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412350TE20
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412350TE20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350TE20IV
Manufacturer:
DALLAS
Quantity:
2 874
No
No
No
Figure 13-12 Sample Multiprocessor Serial Reception Flowchart
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read MPIE bit in SCR
All data received?
This station's ID?
FER ORER= 1
FER ORER= 1
Start reception
Initialization
RDRF= 1
RDRF= 1
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error processing
[4]
[3]
[1]
[2]
(Continued on
next page)
[5]
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error processing and
break detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
processing, ensure that the
ORER and FER flags are both
cleared to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.
575